EasyManua.ls Logo

Lexmark X850E - Exit 2 Diverter Gate Removal

Lexmark X850E
843 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-318 MFP Service Manual
7500-XXX
Exit 2 diverter gate removal
1. Remove the exit 2 unit assembly. See “Exit 2 unit assembly removal” on page 4-315.
2. Open the exit 2 unit assembly.
3. Remove two screws securing the upper guide assembly (A) to the exit 2 unit assembly.
4. Remove the upper guide assembly (A).
Note: The exit 2 access handle (B) may become detached.
5. Remove the spring (C) connecting the exit 2 diverter gate (D) to the upper guide assembly (A).
6. Gently flex the mounting points securing the exit 2 diverter gate (D) to the upper guide assembly (A).
7. Remove the exit 2 diverter gate (D)
Note: After reinstalling the upper guide assembly (A), ensure the exit 2 access handle (B) operates freely.
Boss
A
Front
A
B
C
D

Table of Contents