POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM > DATA LIST / ACTIVE TEST
for Preparation Click here
READ DATA LIST
HINT:
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without
removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or
wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding
whether a part is faulty or not.
a. Connect the intelligent tester to the DLC3.
b. Turn the engine switch on (IG).
c. Turn the intelligent tester on.
d. Enter the following menus: Body Electrical / Tilt & Telescopic / Data List.
e. Check the values by referring to the table below.
Tilt & Telescopic
Tester Display Measurement Item/Range Normal Condition
Diagnostic
Note
Tilt Position
Current tilt position data/min.: 0000 H (0 edges), max.: FFFF H
(65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Telesco
Position
Current telescopic position data/min.: 0000 H (0 edges), max.:
FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Tilt Return
Position
Memorized tilt return position data/min.: 0000 H (0 edges),
max.: FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Telesco Return
Position
Memorized telescopic return position data/min.: 0000 H (0
edges), max.: FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Tilt Memory Pos
1
Tilt data of memory position 1/min.: 0000 H (0 edges), max.:
FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Telesco
Memory Pos 1
Telescopic data of memory position 1/min.: 0000 H (0 edges),
max.: FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Tilt Memory Pos
2
Tilt data of memory position 2/min.: 0000 H (0 edges), max.:
FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Telesco
Memory Pos 2
Telescopic data of memory position 2/min.: 0000 H (0 edges),
max.: FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Tilt Memory Pos
3
Tilt data of memory position 3/min.: 0000 H (0 edges), max.:
FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Telesco
Memory Pos 3
Telescopic data of memory position 3/min.: 0000 H (0 edges),
max.: FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Tilt Up Limit Uppermost tilt position/Not Mem or Mem
Not Mem: Position not memorized
Mem: Position memorized
-
Tilt Up Limit
Position
Uppermost tilt position data/min.: 0000 H (0 edges), max.: FFFF
H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Tilt Down Limit Lowermost tilt position/Not Mem or Mem
Not Mem: Position not memorized
Mem: Position memorized
-
Tilt Down Limit
Position
Lowermost tilt position data/min.: 0000 H (0 edges), max.: FFFF
H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Telesco Short
Limit
Shortest telescopic position/Not Mem or Mem
Not Mem: Position not memorized
Mem: Position memorized
-
Telesco Short
Limit Pos
Shortest telescopic position data/min.: 0000 H (0 edges), max.:
FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
Telesco Long
Limit
Longest telescopic position/Not Mem or Mem
Not Mem: Position not memorized
Mem: Position memorized
-
Telesco Long
Limit Pos
Longest telescopic position data/min.: 0000 H (0 edges), max.:
FFFF H (65535 edges)
7000 to 9000 H
(28672 to 36864 edges)
-
ON: Tilt up activated by manual