EasyManua.ls Logo

LEYBOLD TRIVAC D 16 B-DOT - Replacing the Shaft Seal

LEYBOLD TRIVAC D 16 B-DOT
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37GA01208_002_C0 - 11/2016 - © Leybold
Maintenance
Required tools:
Screwdriver 1.0 x 5.5 mm (for junction box), open-jaw wrenches 7 mm and
19 mm (for junction box), Allan keys 3 mm, 5 mm, 6 mm, possibly a puller for
the coupling.
Disconnect the pump from the mains.
Unscrew the four non-recessed hex. socket screws (11/3).
Remove the intermediate flange (11/5) together with the electric motor (11/4).
Remove the handle (11/2).
Loosen the threaded pin (11/8) and pull the coupling (11/7) with the fan blade
off the motor shaft.
Remove the gasket (11/1).
Unscrew the hex. socket screws (11/6).
Remove the electric motor (11/4).
Clean all parts and check that they are in perfect condition; if not, replace
them with new parts.
Reassemble in the reverse order.
5.8 Replacing the Shaft Seal
Required tools:
Allen keys size 3, 5 and 8, flat-nose pliers, plastic hammer, shaft seal driver,
possibly a puller for the coupling.
Required spare parts:
Shaft seal (12/8) For material No., see spare parts list
Bushing (12/6) For material No., see spare parts list
The TRIVAC-B-DOT has one shaft seal. Oil marks under the coupling hou-
sing are signs of a damaged shaft seal.
The shaft seal (12/8) can be replaced without removing or disassembling the
pump module.
Shutdown the pump.
Drain the oil (see Chapter 5.4).
Support the motor.
Unscrew the four non-recessed hex. socket screws (11/3) and remove the
motor (11/4) with the intermediate flange.
Remove the gasket (11/1).
Remove the coupling element (12/1).
Unscrew the hexagon socket screw (12/2) and remove the spring washer
(12/3).
Pull off the coupling half (12/4).
Remove the key (12/5).

Related product manuals