- 13 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
(2) 3D FHD HDMI EDID data
(3) Detail EDID Options are below
a. Product ID
b. Serial No: Controlled on production line.
c. Month, Year: Controlled on production line:
ex) Week : '01' -> '01'
Year : '2012' -> '16' fix
d. Model Name(Hex):
cf) TV set’s model name in EDID data is below.
e. Checksum: Changeable by total EDID data.
f. Vendor Specific(HDMI)
4.3. Model name & Serial number D/L
▪ Press "Power on" key of service remote control.
(Baud rate : 115200 bps)
▪ Connect RS232 Signal Cable to RS-232 Jack.
▪ Write Serial number by use RS-232.
▪ Must check the serial number at the Product/Service info..
(menu key -> red key -> select product/Service info)
4.3.1. Signal Table
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +...+ Data_n
Delay : 20ms
4.3.2. Comand Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in EEPROM,.
4.3.3. Method & notice
(1) Serial number D/L is using of scan equipment.
(2) Setting of scan equipment operated by Manufacturing
Technology Group.
(3) Serial number D/L must be conformed when it is produced in
production line, because serial number D/L is mandatory by
D-book 4.0.
3D 0 1 2 3 4 5 6 7 8 9 A B C D E F
0 00 FF FF FF FF FF FF 00 1E 6D A B
10 C 01 03 80 A0 5a 78 0A EE 91 A3 54 4C 99 26
20 0F 50 54 A1 08 00 31 40 45 40 61 40 71 40 81 80
30 01 01 01 01 01 01 02 3A 80 18 71 38 2D 40 58 2C
40 45 00 A0 5A 00 00 00 1E 66 21 50 B0 51 00 1B 30
50 40 70 36 00 A0 5A 00 00 00 1E 00 00 00 FD 00 3A
60 3E 1E 53 10 00 0A 20 20 20 20 20 20 D
70 D 01 E
80 02 03 33 F1 4E 10 9F 04 13 05 14 03 02 12 20 21
90 22 15 01 26 15 07 50 09 57 07 F
A0 80 1E 20 C0 0E 01 40 0A 0F 08 10 18 10 98 10 58
B0 10 38 10 01 1D 80 18 71 1C 16 20 58 2C 25 00 20
C0 C2 31 00 00 9E 01 1D 00 72 51 D0 1E 20 6E 28 55
D0 00 20 C2 31 00 00 1E 02 3A 80 18 71 38 2D 40 58
E0 2C 45 00 A0 5A 00 00 00 1E 01 1D 00 BC 52 D0 1E
F0 20 B8 28 55 40 C4 8E 21 00 00 1E 00 00 00 00 E
MODEL NAME HEX EDID Table DDC Function
HD/FHD Model 0001 01 00 Analog/Digital
MODEL NAME MODEL NAME(HEX)
LG TV 00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 (LG TV)
EDID C/S data
3D FHD
HDMI RGB
check sum
(Hex)
Block 0 43 5C
Block 1
23 (HDMI1)
-13 (HDMI2)
03 (HDMI3)
Input Model name(HEX)
HDMI1 78030C001000
HDMI2 78030C002000
HDMI3 78030C003000
Adjust mode CMD(hex) LENGTH(hex) Description
EEPROM WRITE A0h 84h+n n-bytes Write (n = 1~16)
CMD LENGTH ADH ADL DATA_1 . . . Data_n CS DELAY