4. Total Assembly line process
4.1. Adjustment Preparation
■ W/B Equipment condition
est signal : Inner pattern (80IRE) –
■ Above 5 minutes H/run in the inner pattern. (“power on” key of
color temperature and coordinate
- Inner pattern for W/B adjust
- External white pattern
► CA210 : CH 14, Test signal : Inner pattern (80IRE)
- Standard color coordinate and temperature using CA-1000 (by
Connecting picture of the measuring instrument
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER-ON -> Enter
the mode of White-Balance, the pattern will come out.
Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (Illumination is less than 10ux).
the Color Analyzer ( CA210
less than 10cm distance, keep it with the surface of the
Module and Color Analyzer’s Prove vertically.(80~100°).
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others, check