Only for training and service purposes
Cautions) The Time Table of color coordinates by SET Aging Tim
* After done all adjustments, Press “In-start” button and
compare Tool option and Area option value with its BOM, if
it is correctly same then unplug the AC cable. If it is not
same, then correct it same with BOM and unplug AC cable.
For correct it to the model’s module from factory JIG model.
* Push The “IN STOP KEY” after completing the function
inspection.
4.2. DDC EDID Write (RGB 128Byte)
Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For SVC main Ass’y, EDID have to be downloaded to Insert
Process in advance.
4.3. DDC EDID Write (HDMI 256Byte)
• Check whether written EDID data is correct or not.
* For SVC main Ass’y, EDID have to be downloaded to Insert
Process in advance.
4.4. EDID DATA
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
- Auto Download
• After enter Service Mode by pushing “ADJ” key.
• Enter EDID D/L mode.
• Enter “START” by pushing “OK” key.
* Edid data and Model option download (RS232)
<Caution>
- Never connect HDMI & D-sub cable when the user
downloading.
- Use the proper cables below for EDID Writing
- Manual Download
* Caution
· Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
· Never connect HDMI & D-sub Cable at the same time.
· Use the proper cables below for EDID Writing.
· Download HDMI1, HDMI2, separately because HDMI1 is
different from HDMI2.
1) Analog Data 128Byte (2Bi)
2) DIGITAL DATA(HDMI-1/2/3/4) 256Byte
H/R Time Cool Medium Warm
(Min) X Y X Y X Y
269 273 285 293 313 329
1 ~5 281 297 290 307 318 343
2 6~20 280 288 289 301 317 338
3 21~30 278 285 287 297 316 334
4 31~ 276 283 285 293 313 329
Item CMD1 CMD2 Data0
Download A A 0 0 When transfer the ‘Mode In’,
‘Mode In’ Carry the command.
Download A E 00 10 Automatically Download
(The use of a internal Data)
For Analog EDID
For HDMI EDID
D-sub to D-sub DVI-D to HDMI or HDMI to HDMI
No. Item Condition Hex Data
1 ManufacturerID GSM 1E6D
2 Version Digital : 1 01
3 Revision Digital : 3 03
0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0A 0x0B 0x0C 0x0D 0x0E 0x0F
0x00 00 FF FF FF FF FF FF 00 1E 6D
ⓐⓑ
0x01 01 03 68 73 41 78 0A CF 74 A3 57 4C B0 23
0x02 09 48 4C A1 08 00 81 80 61 40 45 40 31 40 01 01
0x03 01 01 01 01 01 01 02 3A 80 18 71 38 2D 40 58 2C
0x04 45 00 7E 8A 42 00 00 1E 01 1D 00 72 51 D0 1E 20
0x05 6E 28 55 00 7E 8A 42 00 00 1E 00 00 00 FD 00 3A
0x06 3E 1E 53 10 00 0A 20 20 20 20 20 20
0x07 00
0x000x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0A 0x0B 0x0C 0x0D0x0E 0x0F
0x00 00 FF FF FF FF FF FF 00 1E 6D ⓐⓑ
0x01 01 03 80 73 41 78 0A CF 74 A3 57 4C B0 23
0x02 09 48 4C A1 08 00 81 80 61 40 45 40 31 40 01 01
0x03 01 01 01 01 01 01 02 3A 80 18 71 38 2D 40 58 2C
0x04 45 00 7E 8A 42 00 00 1E 01 1D 00 72 51 D0 1E 20
0x05 6E 28 55 00 7E 8A 42 00 00 1E 00 00 00 FD 00 3A
0x06 3E 1E 53 10 00 0A 20 20 20 20 20 20
0x07 01
0x00 02 03 26 F1 4E 10 1F 84 13 05 14 03 02 12 20 21
0x01 22 15 01 26 15 07 50 09 57 07 67
0x02 E3 05 03 01 01 1D 80 18 71 1C 16 20 58 2C
0x03 25 00 7E 8A 42 00 00 9E 01 1D 00 80 51 D0 0C 20
0x04 40 80 35 00 7E 8A 42 00 00 1E 02 3A 80 18 71 38
0x05 2D 40 58 2C 45 00 7E 8A 42 00 00 1E 66 21 50 B0
0x06 51 00 1B 30 40 70 36 00 7E 8A 42 00 00 1E 00 00
0x07 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00