4.2.3. Equipment connection MAP
4.2.4. Adj. Command (Protocol)
<Command Format>
CMD ID DATA CR RF
-. CMD: Command
-. ID : Command
-. Data : Command
Ex) [Send: va 00 00\r\n]
▪ RS-232C Command used during auto-adj.
4.2.5. Adj. method
(1) Set TV in POWER-ONLY mode using POWER ONLY key
(2) Zero calibrate probe then place it on the center of the
Display
(3) Connect Cable (RS-232C to USB)
(4) Select Model in “V-com adj. Program” and begin “V-com
adj.”
(5) When V-com adj. is complete (OK)
(6) Remove probe and RS-232C to USB cable to complete
adjustment.
V-com Adj. must begin as start command “va 00 00”, and
finish as end command “wb 00 ff”
▪ V-com adjust data
- 43 inch
- 49 inch
- 55 inch
- 65 icnh
4.3. White Balance Adjustment
4.3.1. Overview
▪ W/B adj. Objective & How-it-works
(1) Objective: To reduce each Panel's W/B deviation
(2) How-it-works : When R/G/B gain in the OSD is at 192, it
means the panel is at its Full Dynamic Range. In order to
prevent saturation of Full Dynamic range and data, one
of R/G/B is fixed at 192, and the other two is lowered to
find the desired value.
(3) Adjustment condition : normal temperature
1) Surrounding Temperature : 25 °C ± 5 °C
2) Warm-up time: About 5 Min
3) Surrounding Humidity : 20 % ~ 80 %
4.3.2. Equipment
(1) Color Analyzer: CA-210 (LED Module : CH 14)
(2) Adjustment Computer(During auto adj., RS-232C protocol
is needed)
(3) Adjustment Remote control
(4) Video Signal Generator MSPG-925F 720p/216-Gray
(Model: 204, Pattern: 49)
→ Only when internal pattern is not available
Color Analyzer Matrix should be calibrated using CS-100.
4.3.3. Equipment connection MAP
4.3.4. Adj. Command (Protocol)
<Command Format>
- LEN: Number of Data Byte to be sent
- CMD: Command
- VAL: FOS Data value
- CS: Checksum of sent data
- A: Acknowledge
Ex) [Send: JA_00_DD] / [Ack: A_00_okDDX]
Color Analyzer
Computer
Pattern Generator
RS-232C
RS-232C
RS-232C
Probe
Signal Source
* If TV internal pattern is used, not needed
START 6E A 50 A LEN A 03 A CMD A 00 A VAL A CS STOP
Flicker Analyzer
Computer
Probe
RS-232C
USB to RS-232C
ӿ If you want to use Signal Source,
you use TV internal Flicker pattern
RS-232C COMMAND
[CMD ID DATA]
Explanation
va 00 00 V-com pattern
vb 00 00 ~ FE V-com adj.(internal Flicker pattern)
wb 00 FF V-com adj. completed
V-com Data
hex dec
Max B4 180
Default 96 150
Min 78 120
V-com Data
hex dec
Max 8B 139
Default 6D 109
Min 4F 79
V-com Data
hex dec
Max 85 133
Default 68 104
Min 49 73
V-com Data
hex dec
Max AB 171
Default 8D 141
Min 6F 111