Copyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
EDID Block 1, Bytes 128-255
# PCM HDMI2 (C/S: E7 E2)
EDID Block 0, Bytes 0-127
EDID Block 1, Bytes 128-255
# PCM HDMI3 (C/S: A1 FC)
EDID Block 0, Bytes 0-127
EDID Block 1, Bytes 128-255
# PCM HDMI4 (C/S: E7 BD)
EDID Block 0, Bytes 0-127
EDID Block 1, Bytes 128-255
* Checksum (HDMI 1/2/3/4)
Input DTS FFh
(Checksum(6G)
DTS FFh
(Checksum(3G)
PCM FFh
(Checksum)
AC3 FFh
(Checksum)
HDMI1 A0 E5 E6 72 8B 8B E7 FD
HDMI2 A0 D5 E6 62 7B 7B E7 ED
HDMI3 E6 52 8A 8A A1 FC
5.3. Camera Port Inspection
(1) Objective : To check how it connects between Camera and
PCBA normally, and their Function
(2) Test Method : This Inspection is available only Power-Only
Status.
i) Push Camera Up
ii) Camera’s Preview picture appears on TV Set
iii) Push Camera Down
(3) RS-232C Command
RS-232C COMMAND
Explanation
CMD DATA ID
Ai 00 23 Camera Function Start.
Ai 00 24 Camera Function End.