EasyManua.ls Logo

LG 60UU640C - Page 56

LG 60UU640C
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Check Sequence
1. AC input Check : SK100 (100~240Vac)
2. PWR-ON Check :
- SET On : above 3V
- SET St-by : 0V
3. 13.2V Level Check : J10
- SET On : 13.2V
- SET St-by : 8.4V (swing between 7V to 10V)
4. DRV_ON Check :
- SET On : above 3V
- SET St-by : 0V
5. LED voltage Check : P202 to P203
6. LED Indicator Check
- Normal condition : Not blank
- Abnormal condition : Blank 1~9 times
Established
date
Standard Repair Process Detail Technical Manual
Revised
date
A18
Content
Check power input voltage and ST-BY 8.4V
B. Power error _No power
SET Model
Power P/N, Name
65UU64
EAY64470301, LGP6065L-17UL6
SK100 (AC input)
Power Board Voltage / Current
P202,P203
Picture Condition : VIVID (Backlight 100)
Rated Current [Amean]
0.66A (110mA 6string)
A18
DRV_ON (J35)
13.2V (J3)
PWR_ON
(J45)
LED Indicator
All condition meets, Power Board OK.
Error
symptom
Copyright © 2018 LG Electronics. Inc. All rights reserved.
Only for training and service purposes.

Other manuals for LG 60UU640C