EasyManua.ls Logo

LG 65UU640C - RS-232 C Communication Protocol; RS-232 C Connector and Configurations; Set ID Configuration

LG 65UU640C
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
20
Connector type : D-Sub 9-pin male
1
6
5
9
RS-232C
(Serial port)
RS-232C configurations
7-Wire Configurations
(Standard RS-232C cable)
3-Wire Configurations
(Not standard)
PC TV
RXD 2 3 TXD
TXD 3 2 RXD
GND 5 5 GND
DTR 4 6 DTR
DSR 6 4 DSR
RTS 7 8 RTS
CTS 8 7 CTS
D-Sub 9 D-Sub 9
PC TV
RXD 2 3 TXD
TXD 3 2 RXD
GND 5 5 GND
DTR 4 6 DTR
DSR 6 4 DSR
RTS 7 8 RTS
CTS 8 7 CTS
D-Sub 9 D-Sub 9
Set ID
For Set ID number, see “Real data mapping (Hexadecimal : Decimal)”.
1 Press (Q.Settings) / ( ) to access the main menus.
2 Press the Navigation buttons to scroll to (* [General] [Set ID]) and press / button.
3 Scroll left or right to select a set ID number and select / (Back) The adjustment range is 1-99.
4 When you are finished, press .