EasyManuals Logo

LG AMNH07GD4L0 User Manual

LG AMNH07GD4L0
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #198 background imageLoading...
Page #198 background image
198 Multi type Air Conditioner
Troubleshooting Guide
3) Troubleshooting CH04
Check the resistance
0
CN Float
CN-Float
CN-D/PUMP
04
Drain pump
/ Float switch
Float switch Open.
(Normal : short)
The connection of wire(Drain pump/ Float switch)
Drain pump power input. (220V)
Drain tube installation.
Indoor unit installation. (Inclination)
Display
code
Title Cause of error Check point & Normal condition
Check Point
1. Check the wire connection. (Open, Soldered poorly) Repair the connection or change the PCB.
2. Check the resistance of float switch (Abnormal : Open, Normal : short) Check the float switch.
3. Check the level of water
4. Check the volt. Of Drain pump power supply. (AC 230V) Repair or Change the main PCB.

Table of Contents

Other manuals for LG AMNH07GD4L0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG AMNH07GD4L0 and is the answer not in the manual?

LG AMNH07GD4L0 Specifications

General IconGeneral
BrandLG
ModelAMNH07GD4L0
CategoryAir Conditioner
LanguageEnglish

Related product manuals