Cooling Capacity Tables
ARNU183NJA4
VERTICAL / HORIZONTAL AIR HANDLER
Table 132: ARNU183NJA4 Cooling Capacity Table.
Model No./
Capacity Index
Outdoor
Air Temp.
(°F DB)
Indoor Air Temperature (°F DB / WB)
68 / 57 73 / 61 79 / 64 80 / 67 85 / 70 88 / 73 91 / 76
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
ARNU183NJA4/
18.0
-9.9 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
-5 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
0 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
5 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
10 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
14 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
20 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
23 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
25 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
30 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
35 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
40 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
45 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
50 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
55 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.3 13.6
60 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 23.0 13.5
65 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 22.7 13.3
70 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 22.4 13.1
75 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 21.5 13.6 21.8 12.8
80 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.2 13.7 20.9 13.5 21.2 12.7
85 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 20.0 13.6 20.2 12.9 20.6 12.2
90 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 19.7 13.4 19.8 12.7 20.2 12.1
95 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 19.3 13.3 19.7 12.7 20.0 11.9
100 11.9 9.8 14.4 11.3 16.2 12.0 18.0 12.8 18.9 13.1 19.3 12.5 19.7 11.9
105 11.9 9.8 13.7 10.7 15.5 11.5 17.3 12.2 17.9 12.2 18.5 12.1 19.1 11.6
110 11.6 9.5 13.0 10.1 14.4 10.7 16.2 11.5 17.0 11.5 17.6 11.5 18.4 11.2
115 11.3 9.2 12.3 9.6 13.5 10.1 15.2 10.9 15.9 10.9 16.7 10.9 17.6 10.8
118 11.0 8.9 11.7 9.1 12.9 9.5 14.6 10.4 15.2 10.4 16.0 10.4 16.9 10.3
122 10.7 8.7 11.1 8.7 12.2 8.9 13.8 9.9 14.4 9.9 15.1 9.9 16.3 9.9
Low ambient performance with LGRED° heat technology is included in Multi V 5 Air Source Units produced after February 2019.
TC: Total Capacity (MBh); SHC: Sensible Heat Capacity (MBh).
Cooling range with the Low Ambient Baffle Kit (sold separately) installed on the outdoor
unit(s) is -9.9°F to +122°F, and is achieved only when all indoor units are operating in
cooling mode. Does not impact heat recovery system synchronous operating range.
The System Combination Ratio must be between 50–130%.
Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change
without notice.
Current certified ratings are available at www.ahridirectory.org.
For outdoor unit performance data, see the respective outdoor unit performance data
manuals on https://lghvac.com/commercial.