EasyManua.ls Logo

LG ART COOL LAN090HSV5 - Page 28

LG ART COOL LAN090HSV5
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
28 | PRODUCT DATA
Single Zone Art Cool
TM
Mirror Wall Mount Engineering Manual
Figure 24: LA90HSV5 and LA120HSV5 General Power / Communica-
tions System Schematic.
Figure 25: LA181HSV5 General Power / Communications System
Schematic.
Use a conduit for the communications cable / power wiring from the outdoor unit to the indoor units.
Make sure the communications cable / power wiring from the outdoor units to the indoor units, and the power wiring to the outdoor unit are
separate, otherwise, the outdoor unit operation may be affected by electrical noise and will malfunction or fail.
208/230 VAC
Figure 26: LA090-120HSV5 System Electrical Connections. Figure 27: LA181HSV5 System Electrical Connections.
Power Supply
Circuit Breaker
Ground Wiring
Outdoor Unit
Indoor Unit
Power Supply
Circuit Breaker
Ground Wiring
Outdoor Unit
Indoor Unit
ELECTRICAL CONNECTIONS