12 | PRODUCT DATA
Art Cool Mirror Wall Mounted Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
LAU090HSV2, LAU120HSV2
GENERAL DATA
Type Art Cool Mirror
System (Model) LA090HSV2 (LAN090HSV2/LAU090HSV2) LA120HSV2 (LAN120HSV2/LAU120HSV2)
Piping
Liquid Line (in, OD) 1/4
Vapor Line (in, OD) 3/8
Condensation Line (OD | ID) 27/32 | 5/8
Additional Refrigerant Charge (oz/ft) 0.22
Max Pipe Length (ft)
5
65.6
Piping Length (no add’l refrigerant, ft)
5
41
Max Elevation Difference (ft) 32.8
EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit
Power wiring is field supplied and must comply with the applicable local and national codes.
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
5
Piping lengths are equivalent.
Table 2: Unit General Data (Continued)