16 | PRODUCT DATA
Art Cool Premier Wall Mount Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
REFRIGERANT FLOW DIAGRAM
LAN090HYV, LAN120HYV
LAU090HYV, LAU120HYV
tinU roodtuOtinU roodnI
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
Compressor
Accumulator
Gas Side
3-Way Valve
2-Way Valve
Liquid Side
Cooling
Heating
Reversing Valve
EEV
Th1
Th6
Th3
Th7
Th4
Th5
LOC. Description PCB Connector
Th1 Indoor air temperature thermistor CN-TH1(Indoor)
Th3 Water level sensor (Option) CN-TH2 (Indoor)
Th4 Evaporating middle temperature thermistor CN-TH3 (Indoor)
Th5 Discharge pipe temperature thermistor CN-TH2 (OUTDOOR)
Th6 Heat exchanger temperature thermistor CN-TH1(OUTDOOR)
Th7 Outdoor air temperature thermistor CN-TH1(OUTDOOR)
EEV : Electronic Expansion Valve