30 Room Air Conditioner
Operation
LED display of indoor unit
Operation
OEM Brand
LG Brand/OEM Brand
Operation
indicator
Shape of
display
Setting
temp.
Standard Too hot Hot Cold Too cold
Jet
(Cool, Heat)
Test
operation
Comfortable
A.I operation mode
Cooling
heating
dehumidifi-
cation
Energy save
in cooling
mode
PLASMA
Operation Indicator
Sleep Timer Indicator
PLASMA Indicator
Timer Indicator
Preheat Indicator
Setting Temp.
On while in appliance operation, off while in appliance pause.
Blinking(3sec off/0.5sec on) according to Error Code as long as the system malfunctions.
On while in sleep timer mode, off when sleep timer cancel or appliance operation pause.
On while in plasma mode, off when plasma mode cancel.
On while in timer mode(on/off), off when timer mode is completed or canceled.
Off except when hot start during heating mode operation or while in defrost control.
Cooling/heating/dehumidification mode : setting temperature from remote control
Fuzzy operation mode : fuzzy key data(5sec on) AI
Operation Indicator
Power Saving Indicator
Timer Indicator
Preheat Indicator
On while in appliance operation, off while in appliance pause.
Flashing while in disconnection or short in Thermistor. (3 sec off/0.5 sec on)
On while in power saving cold mode, off when power saving cold cancel.
On while in timer mode(on/off) and sleep timer mode (on), off when timer mode is
completed or canceled.
Off except when hot start during heating mode operation or while in defrost control.