4. Trouble Shooting 
Items Contents
Purpose
Prevention of the damage of PCBA, wire, and connector caused by 
over-current
Condition for Generation The detected current exceeds the standard.
Expected 
Causes
Installation & 
Overload
Installation fault, closing of SVC valve, under/over charging with refriger-
ant, infiltration of water into refrigerant, outdoor device shielding, outdoor 
fan fault, EEV valve fault, and sensor fault or assembling error.
Compressor
Short between compressor coil and sash, abrasion of compressor, and 
short/opening of compressor coil.
PCB 
Assembly
Input current detection circuit fault.
Others Input of low-voltage.
6.7 Troubleshooting Outdoor Error 