Is the drain pan filled 
half with condensate 
water? (half level of 
float switch)*
Is drain pump working?
(Sound/drain noise/
contact etc.)
Replace float switch
Replace Indoor PCB or 
reconnect the connector
Yes 
Yes 
No 
No 
Is Float switch short 
On measuring its 
resistance?  
No 
Yes 
Drain pump blocked by
foreign particles?
Yes 
No 
In indoor unit PCB 
Does the terminal voltage 
for drain pump has 
220V output?**
Replace indoor unit PCB
Replace Drain Pump
Yes 
Check the drain head height 
and slope***
Remove it & clean the pump
float
Checking float
switch
No 
Condensate water
 (Low position   short   0 ohm )
* If the float goes up higher than a half of float 
switch then the circuit is open & the unit is 
stopped automatically.
(High position   Open)