EasyManua.ls Logo

LG DLEX3250 Series - Connecting Electric Dryers

LG DLEX3250 Series
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22 23
130#-&.
This is normal.•Steam is released at different stages of the cycle
for each option.
Cannot see steam
vapor at the
beginning of cycle.
MORE TIME button
pressed.
Pressing the MORE TIME button several times will
set the cycle for a large load such as a comforter.
The display shows
BULKY LOAD.
•STEAM FRESH™ did
not remove odor
completely.
•Fabrics containing strong odors should be washed in
a normal cycle.
Odors remain in
clothing after
STEAM FRESH™.
1044*#-&$"64&4 40-65*0/4
%*41-":
Thermistor of blower
housing
Outlet thermistor open or shorted.
tE1
$)&$,*/(1"35 $"64&
•tE1 error is displayed in the
drying cycle or test mode.
Thermistor of blower
housing
Outlet thermistor open or shorted.
tE2
•tE2 error is displayed in the
drying cycle or test mode.
Thermistor of steam
generator
Steam generator thermistor open
or shorted.
tE4
•tE4 error is only displayed in the
test mode.
•Replace the steam generator.
Water supply pump
When the pump valve is less than
10 in the test mode
E5
•tE5 error is only displayed in the
test mode.
•Check the connection between
harness wire and connector.
•Replace the water supply pump.
Steam generator
Sensors do not detect that steam
generator is full within 60 seconds.
Add water
If water in the steam feeder is
not enough this error may be
displayed. Fill the feeder and
restart the cycle.
3&."3,
8-3. Display Fault/Error Codes for Steam Dryer
The error codes below will be displayed when attempting to start a drying cycle or after
activating the Diagnostic Test mode.
9
FLOW SENSOR FUNCTION
This FlowSense
TM
function detects the clogging or blocking of ducts.
Clogged duct vents or hoses decrease efficiency in drying cloths. Clogged vents can also cause fire.
This function alerts you to the need of cleaning the duct.
When the alarm about Duct clogging is on display of the panel, your duct vents should be cleaned by
yourself or serviceman.
9-1 Flow sensor
Flow Sensor Function

Other manuals for LG DLEX3250 Series

Related product manuals