14
SECURE THE CURTAIN FRAMES
Expand the curtain frames and secure them using 5
screws (ITEM E) as shown in FIG. 7.
When curtain frame opens or closes, you may feel a
slight resistance. This is normal.
FOAM SEAL AND WINDOW LOCK
• Cut the foam seal (ITEM F) to the window width.
Stuff the foam seal between the glass and the
window to prevent air and insects from getting into
the room, as shown in FIG.7.
• Install the L bracket to prevent window from being
raised which may result in unit falling.
NOTE: If window sash has a metal surface. use sheet
metal screws instead of the provided wood screws.
Obtain sheet metal screws at local hardware store.
IF AIR CONDITIONER IS BLOCKED
BY STORM WINDOW FRAME
• If storm window presents interference, fasten a
2"(51mm) wide wood strip to the inner window sill
across the full width of the sill. The wood strip should
be thick enough to raise the height of the window sill
so that unit can be installed without interference
from the the storm window frame. See FIG. 8.
Top of wood strip should be approximately
3/4"(19mm) higher than the storm window frame to
help condensation to drain properly to the outside.
• Install a second wood strip (approximately
6"(152mm) long by 11/2"(38mm) wide and same
thickness as first strip) in the center of the outer sill
flush against the back of the inner sill. (FIG. 8)
INSTALLATION FOR OTHER TYPE
WINDOWS.
• Dimensions and geometry of windows are different
according to manufacturers. Check your window and
refer to FIG.9 to install the support bracket firmly.