Input power of Environmental controlled anti-condensation
heater / Defrost period
GR-B24FWAHL / GR-B24FWSHL
Mullion heater
Relative
Humidity
Running rate in percentage(R) at
the ambient temperature(i)(%)
Input power at the ambient
temperature
16°C 22°C 32°C 16°C 22°C 32°C
0-10% 0.00 0.00 0.03 1.765 1.765 2.941
10-20% 0.06 0.06 0.33 1.765 1.765 2.941
20-30% 0.60 1.62 2.35 1.765 1.765 2.941
30-40% 2.76 9.24 2.56 1.765 1.765 2.941
40-50% 6.93 12.72 3.57 1.765 1.765 2.941
50-60% 8.01 11.70 1.11 3.941 3.941 5.411
60-70% 5.55 11.40 0.05 3.941 3.941 5.411
70-80% 3.30 7.92 0.00 3.941 3.941 5.411
80-90% 1.80 3.48 0.00 5.882 5.882 5.882
90-100% 0.99 1.86 0.00 5.882 5.882 5.882
GR-B24FWVFC
Mullion heater
Relative
Humidity
Running rate in percentage(R) at
the ambient temperature(i)(%)
Input power at the ambient
temperature
16°C 22°C 32°C 16°C 22°C 32°C
0-10% 0.00 0.00 0.03 0.000 0.000 0.000
10-20% 0.06 0.06 0.33 0.000 0.000 0.000
20-30% 0.60 1.62 2.35 0.000 0.000 0.000
30-40% 2.76 9.24 2.56 0.000 0.000 1.513
40-50% 6.93 12.72 3.57 0.000 0.000 2.017
50-60% 8.01 11.70 1.11 0.756 1.513 3.025
60-70% 5.55 11.40 0.05 1.513 2.017 4.033
70-80% 3.30 7.92 0.00 2.017 2.269 4.538
80-90% 1.80 3.48 0.00 3.025 5.042 5.042
90-100% 0.99 1.86 0.00 3.529 5.042 5.042
Environmental controlled anti-condensation heater
Anti-condensation heaters are turned on and off according to the control logic,
which is affected by ambient temperature and humidity condition in a normal
temperature setting. (Freezer compartment -18°C, Refrigerator compartment 4°C),
The input power of environmental controlled anti-condensation heater is given in
below table.