EasyManua.ls Logo

LG GR-L227 - Page 31

LG GR-L227
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-6. Door opening sensing circuit
(1) GR-P227/L227
EXPLATION FOR MICOM CIRCUIT
- 31 -
Since door switch sensing switch (A), (B) are a separate switch even if the door switch of the freezing room normally
operates, they may fail to sense door opening in the failure of switch at both ends of (A) and (B) or in failure of the L/wire.
Lamp does at the cold storage room not turn on if the door switch of the cold storage room fails to sense the door open
switch (c ), (d) or the home bar switch.
Closing 5 V ( A - B , C - D, E - F . S/W at both ends are at Off status)
Opening 5 V ( A - B , C - D, E - F . S/W at both ends are at On status)
Measuring part
IC1 (MICOM) No. 47, 46 Pin
Door of Freezing/Cold Storage Room

Related product manuals