1-8. Switch entry circuit
The following circuits are sensing signal form the damper motor reed switch for testing and diagnosing the refrigerator.
(1) GR-P227/L227
1-9. Option designation circuit (model separation function)
(1) GR-P227/L227
The circuits shown above vary according to which features are included on your particular model.
uThese circuits are preset at the factory and cannot be altered.
EXPLATION FOR MICOM CIRCUIT
- 33 -
Separation Connection Status Application Standard
Connection Miracle Zone exist
OP1
OUT Miracle Zone don’t exist