TROUBLE DIAGNOSIS
- 100 -
Problems Symptom Causes Checks Measures Remarks
Bad defrost. Defrost is not Defrost lead wire is cut. Check if defrost lead wire is cut with a  Reconnect Lead 
working. tester. Wire.
Defective defrost driving relay. Check the voltage of CON2 (1 and 7)  Replace relay (RY 7 Refer to load
with a tester after pressing main  and RY 3) or PCB. driving conditions
PCB test switch twice.  check in circuit 
If the voltage is normal then it is OK. explanation.
Defective defrost sensor parts. Check the resistance of defrost sensor  Replace defrost  Refer to sensor 
with a tester. sensor. resistance
characteristic
table of circuit
explanation.
Defective  Buzzer  Defective connecting lead wire from  Check lead wire related to door  Repair lead wire.
buzzer continuously main  PCB to door switch. switch with a tester.
rings or door Defective door switch parts. Refer to door switch in parts repair Replace door switch.
opening alarm  guide.
does not work.
Defective  Buzzer does  Key input wire is cut or bad connector  Check input wire with a tester. Reconnect lead  Refer to display
display button not ring and  terminal contact in main PCB and  wire and replace or  circuit in circuit
key does not display PCB connecting lead wire. directly connect bad explanation.
sense even  contact terminal to
button is  lead wire.
pressed.
Key is continuously depressed due to  Disassemble frame display and confirm  Adjust or replace
structural interference. visually. interfering 
structures.