61
Before Installation
INSTALLATION
Before Installation
Dimensions and
Clearances
Too small of a distance from adjacent
items may result in the degradation of
freezing capability and increased
electricity costs. Allow over 50 mm of
clearance between the back of the
appliance and the wall when installing
the appliance.
• Refer to the label inside the appliance
to determine which type your
appliance is.
Ambient Temperature
• The appliance is designed to operate
within a limited range of ambient
temperatures, depending on the
climate zone.
• The internal temperatures could be
affected by the location of the
appliance, the ambient temperature,
the frequency of door opening and so
on.
• The climate class can be found on the
rating label.
* Australia, India, Kenya
** Argentina
- Size (mm)
A913
B1 790
C735
D620
E691
F735
G1 180
H1 635
Climate Class Ambient
Temperature Range
ºC
SN (Extended
Temperate)
+10 - +32
N (Temperate) +16 - +32
ST (Subtropical) +16 - +38 / +18 -
+38**
T (Tropical) +10 - +43* / +16 -
+43 / +18 - +43**