EasyManua.ls Logo

LG LB-E4881HL - Page 18

LG LB-E4881HL
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HEAT PUMP
Model : LB-E4881HL/LB-E4883HL/LB-E6081HL/LB-E6083HL
COOLING ONLY
Model : LB-E4881CL/LB-E4883CL/LB-E6081CL/LB-E6083CL
18
OUTDOOR WIRING DIAGRAM INDOOR WIRING DIAGRAM
R
TERMINAL
BLOCK
POWER SUPPLY
POWER
RELAY
STN
BK
BK
BK
WH
WH WH
RD
OR
BK
HIGH PRESSURE S/W
WH
Deice PCB
CTH
TNS
NO
NC
WH
OR
BK
POWER
RELAY
1
2
3
4
5
6
31
T/B1
T/B2
32
B
A
FAN
MOTOR
FAN
MOTOR
YL BK
OR
BK
T3
T2
T1
RD
WH
COMP.
12
34
56
78
YL BK
OR
BK
BK
BL
BL
BK
WH
CAPACITOR CAPACITOR
REVERSING
VALVE
BR
BL
BR
BL
GN/YL
GN/YL
TERMINAL BLOCK
To the indoor unit
1
2
3
4
5
6
BK
WHWH
YL
BK
RD
Fuse
(250V 5A)
Fuse
(250V 5A)
INDOOR
MOTOR
DRAIN
PUMP
BR
BR
YL
OR
RD
BL
BL
RD
BK
BL
BL
BK
GN/YL
GN/YL
COMP
4 WAY
FUSE
250V10A
TEMP.
THERMISTOR
PIPE
THERMISTOR
FLOAT S/W
REMOTE
CONTROL
ZONE
CONTROL
OPTION
TERMINAL
BLOCK
1
(
L
)
2
(
N
)
4 3
5
TO OUTDOOR UNIT

Table of Contents