Installation Manual 17
ENGLISH
Installation of Indoor, Outdoor Unit
Flared connection (Union)
Flared connection
(Service valve, Ball valve)
Use a seemliness tube
Factory charged
Indoor
Outdoor
Select the following location
A place where the air conditioner can get good ventilation.
A place where it shall not annoy the neighbors.
A place where the unit shall be leveled and that can support the weight of unit and
withstand its vibrations.
Keep a maintenance space
REFRIGERANT PIPING
INSTALLATION OF OUT DOOR UNIT
Perform the work according to the Service Manual or
Installation Guide.
Select a location that satisfies the following
conditions. Install the unit firmly in place.
Use two spanners when connecting the
refrigerant pipe to the unit.
Make a bend with a radius as large as
possible.
Perform air purge with R-22 or vacuum
drying.
When piping work is finished, check all
joints.
Add refrigerant if piping is over 7.5m.
Above 70Cm
Above 30Cm
Outdoor unit
Above 30Cm Above 50Cm
Face of wall
Capacity Addition volume
60k Btu/h(3ø) 85 g/m