EasyManua.ls Logo

LG LFX23961SW /01 - 8-1-15 Test Mode

LG LFX23961SW /01
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. The Test mode allows checking the PCB and the function of the product as well as finding out the defective part in case of
an error.
2. The test mode is operated by pressing test button at main PCB controller.
3. While in the test mode, the function control button is not recognized, but the recognition tone sounds.
4. After exiting the test mode, be sure to reset by unplugging and then plugging in the appliance.
5. If an error, such as a sensor failure, is detected while in the test mode, the test mode is cleared and the error code is
displayed.
6. While an error code is displayed, the test mode will not be activated.
Table 1. Function Test
- 33 -
MODE OPERATION FUNCTION REMARKS
TEST1
TEST2
TEST3
RESET
1) Continuous operation of the
COMPRESSOR and the Freezer fan
2) Stepping DAMPER OPEN
3) Defrosting HEATER OFF
4) DISPLAY LED all ON
1) Continuous operation of the
COMPRESSOR and the Freezer fan
2) Stepping DAMPER CLOSE
3) Defrosting HEATER OFF
4) DISPLAY LED shows no. 2
1) COMPRESSOR and the Freezer fan
OFF
2) Stepping DAMPER CLOSE
3) Defrosting HEATER ON
4) DISPLAY LED shows no. 3
Reset to the previously setting
Before TEST MODE.
Push Test Switch (in the
main Board) once.
Push TEST Switch
once in TEST
MODE1.
Push TEST Switch once
in TEST MODE 2.
Push TEST Switch
once in TEST
MODE3.
Reset if the
Temperature of the
Defrosting Sensor is
46ºF(8ºC)or more.
The compressor will
Start after a 7-minute
Delay.
Maximum test time:
5 minutes
Maximum test time:
5 minutes
8-1-15 TEST Mode