EasyManua.ls Logo

LG LFX2597 Series - Damper and Freezer Fan Motor Troubleshooting

LG LFX2597 Series
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 38 -
No
5
Checking flow
Damper checking method.
Inputting TEST Mode,
Check the damper and PCB.
6 Check the F-Fan Motor.
Rotate fan using your hand.
It feel sticky, change the motor.
(cause of ice or rust inside of motor)
Result & SVC Action
(1)
(4)
(3)
(2)
1 Mode
2 Mode
1, 2 mode
Closed
Open
Not working
Damper is
normal.
(Go to the 7)
Change the
damper
Damper state
SVC Action
Test
Mode
(1) To (2)
(3) To (4)
270 ~ 330
Other
270 ~ 330
Other
It’s normal
Change damper
It’s normal
Change damper
Result
SVC Action
Test
Point
<CON7>
(1)Pin8, (2)Pin10, (3)Pin12
StickyMotor Change the motor
Point Result SVC Action
7 Check the F Fan motor voltage.
Below 7 V
0 or 5 V
(2) ~ (3)
(1) ~ (3)
Change the Main PCB
Change the F Fan
Point Result SVC Action

Related product manuals