8-11 Condenser Fan Error (Er CF)
No
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Check the fan rotating.
While
an
error
code
is
displayed,
the
fan
is
not
working.
3 Check the Fan motor and surrounding. Rotate fan using your hand.
It feel sticky, change the motor.
Result & SVC Action
4 Check the Fan motor voltage.
Status
No windy
Windy
SVC Action
Check motor
Go to the 4
Below 10 V
0 or 5 V
(1) ~ (2)
(1) ~ (3)
Change the PCB
Change the motor
Point Result SVC Action