6. TROUBLESHOOTING
6-1 Error Code Summary
WARNING: When checking Resistance values, make sure to
turn off the power, and wait for the voltage to
discharge.
NOTE) Within 3 hours after the error : Press the Ice Plus button and Freezer button simultaneously
3 hours after the error : All errors, except for "E rt", "E SS",
"E IS(except for Icing sensor)", "E gF", "E It" error, are displayed.
"E IS" which is displayed without input of user is the error of Icing Sensor.
NO
Error Detection
Category
1 Normal None Normal operation of Display
2
Freezer Sensor
Error
EFS
Short or Disconnection
of Freezer Sensor
3
Refrigerator
Sensor Error
ErS
Short or Disconnection
of Refrigerator Sensor
Check each sensor at it’s
connector.
Error Generation Factors
Remark
Error Display
4
Defrosting
Sensor Error
FdS
Short or Disconnection
of Defrosting Sensor
5
Icing Sensor
Error
EIS
Short or disconnection of
the sensor about Ice maker
(Icing sensor, Ice maker
sensor)
6
Pantry sensor
error
ESS
Short or Disconnection
of Pantry Sensor
10 Poor Defrosting F dH
Even though it is passed
1 hour since then Defrosting,
if Defrosting sensor is not
over 46°F(8°C), it is caused
Temperature Fuse
Disconnection, Heater
disconnection, DRAIN Jam,
Poor Relay for Heater
8
Ice maker kit
defect
Eit
Other Electric system error
such as moter, gear, Hall IC,
operation circuit within I/M kit
When the ice does not drop
even when the I/M Test S/W
is pressed
9
Flow
Meter(Sensor)
Defect
EgF
Error of flow meter or water
input or low water pressure
Error of flow meter or water
input or low water pressure or
flow meter connection
11
Abnormality of
BLDC FAN Motor
for Ice Making
EIF
It is caused when feedback
signal isn’t over 65 seconds
during BLDC FAN motor
operating
Poor BLDC Motor connection,
DRIVE IC, and TR
12
Abnormality of
BLDC FAN Motor
for Freezer
EFF
It is caused when feedback
signal isn’t over 65 seconds
during BLDC FAN motor
operating
Poor BLDC Motor connection,
DRIVE IC, and TR
14
Abnormality of
BLDC FAN Motor
for Mechanic
Room
ECF
It is caused when feedback
signal isn’t over 65 seconds
during BLDC FAN motor
operating
Poor BLDC Motor connection,
DRIVE IC, and TR
15
Communication
Error
ECO
Communication Error
between Micom of Main PCB
and Display Micom
Poor Communication
connection,Poor TR of
Transmitter and Receiver
Tx/Rx between display and
main board.
7
Room Temp
Sensor Error
Ert
Short or Disconnectoin of
Room temp.sensor
13
Abnormality of
BLDC FAN
MOTOR For
Refrigerator
ErF
It is caused when feedback
signal isn’t over 65 seconds
during BLDC FAN motor
operating
Poor BLDC Motor connection,
DRIVE IC, and TR
Freezer
Temperature
(Error code
)
Refrigerator
Temperature
(Error code )
16
Humidity Sensor
Error
EHS
Short or Disconnection of
Humidity Sensor
Poor connection of housing,
missing Humidity sensor,
sensor defect itself, short or
disconnection of harness

Table of Contents