EasyManua.ls Logo

LG LFXS24623B - 8-3 Icing Sensor Error (E IS)

LG LFXS24623B
107 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-3 Icing Sensor Error (E IS)
Symptom Check Point
1. E IS 1. Check for a loose connection
2. Check Sensor Resistance
Resistance [Ω]
CON5
15
th
pin ~ 17
th
pin
Short 0
Open OFF
Other Normal
CON5
15
th
pin ~ 17
th
pin
Resistance [ ]Ω
-22ºF /-30ºC 40k
-13ºF /-25ºC 30k
-4ºF /-20ºC 23k
-13ºF /-25ºC 17k
14ºF / -10ºC 13k
23ºF / -5ºC 10k
32ºF / 0ºC 8k
CON5

Table of Contents