12. TROUBLESHOOTING
Month
1 : January O : October
N : November
9 : September D : December
~
The information tag provides compressor model, refrigerant, serial number and safety approval
There are two types of controllers used in the linear compressor system.
- The “A”-inverter system is used with theFLB075L*NA compressor.
Name Plate
Compressor Label
12-1 INFORMATION OF LINEAR COMPRESSOR
FLB075LANA
Size : 90mm X 20mm
1. Compressor Model
2. Refrigerant
3. Serial Number
4. Safety Approval
Ex)
FLB075L*NA
00 00 9 2003 5 13 0012
Series name
DLF/FA/FB/FLA/FLB
Operating Type
A : A-Inverter
E : E-Inverter
Rated Voltage
& Frequency
- M : 220V 50/60Hz
- N : 115V 50/60Hz
Efficiency version
A:1
st
generation
B:2
nd
generation
Displacement
ex)90=9.0cm³ /stroke
Application Category
- L : LBP with R134a
- H : HBP with R134a
- N : LBP with R600a
Buyer Code
Model Code
Line
Serial No.
Date
Year
**CVCF : Constant Voltage Constant Frequency
FLB075L*NA
E-Inverter
System
Refrigerator
Comp Drive
Inverter
VVVF
Compressor
Stroke
Modulation
Controls the
algorithm
according to
various
conditions.
**CVCF : Variable Voltage Variable Frequency