To reduce noise level, the piston stroke is slowly increased to full power during start up.
There are 6 protection logics designed to protect the linear compressor system. When a failure is detected,
the compressor will shut and will try to restart after a set period of time for each type of failure. The LED
located on the inverter drive PCB will flash the appropriate code to indicate the detected failure. This code will
continue to flash until the unit is disconnected from the power source.
Inverter Error Codes
Step 1) Start up - Half stroke interval for first 30
seconds.
Step 2) Ramp up - Stroke increases every 0.8sec until
maximum stroke length is reached (about 3
min, 15 sec)
Step 3) CVCF interval - 180V / 60Hz
Step 1) Start up - Half stroke interval for first 20
seconds.
Step 2) Ramp up - Stroke increases until maximum
stroke length is reached (about 1 min, 40 sec)
Step 3) VVCF interval - target voltage and frequency
controlled by Control Board signals
Inverter Error
Codes
code Requirement Off Time The number
of LED
flashes
FCT0 5 |Vm, Im|> 2.5V+20% @ COMP off 30s 1
Stroke 10 |Stroke|>17.5mm 60s 2
No Connect 15 |Stroke|<=9.4mm &
While 4 seconds |AC Current|<0.05A
40s 3
Lock 25 |AC Current|>1.0A & |Stroke|<3.0mm 150s 5
Current 30 |Current|>3Ap 360s 6
IPM 35 uc_Fo_Trip!= 0 20S 7
Communication
Error
- Checksum error 0 8