13-2-5 Test Function
1. It is to force the operation during operation test, service, and cleaning. The test switch is mounted under the automatic
ice maker. The test function starts when the test switch is pressed for more than 0.5 second.
2. Testbuttondoesnotworkduringiceejectionandwatersupply.Itworkswhenitisinthehorizontalconditions.Ifmouldis
fulloficeduringtestfunctionoperation,iceejectioncontrolandwatersupplycontroldonotwork.
3. Whentestswitchispressedformorethan0.5secondinthehorizontalconditions,iceejectionstartsirrespectofthe
mould conditions.
Water shall be splashed if test switch is pressed before the water in the mould freezes. Water shall be
suppliedwhilethemouldreturnstothehorizontalconditionsaftericeejection.Thereforetheproblemsoficeejection,
returning to the horizontal conditions, and water supply can be checked by test switch. When test function performs
normally, buzzer sounds and water supply shall carry out. Check it for repair if buzzer does not sound.
4. When water supply is completed, the cycle operates normally as follows: Ice makingIceejection
Returning to
horizontal conditions
Water supply
5.Removeicefromtheicemakercubemouldandpresstestswitchwhenicemakercubemouldisfulloficeasiceejection
and water supply control do not work when cube mould is full of ice.