EasyManua.ls Logo

LG LFXS32726 Series - Page 74

LG LFXS32726 Series
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 74 -- 74 -
10-2 Sheath Heater (Freezer Room)
Function Sheath heater is the part for defrost. All heating wire is connected to only one line. So we
can decide part is defective or not when we check the resistance.
How to
Measure
Set a ohmmeter connect to The housing pins.
Measure the pins connected to Sheath Heater.
If the ohmmeter indicates (VxV)/P=R (V=voltage, P=watt, R=Resistance) is on a good condition,
ex) watt=200W, voltage=115V R=(115x115)/200=66
Infinitive value implies sheath heater is disconnected.
Standard
Sheath heater (at all temperature)
Test Point
(1) to (2)
Ressult
60 ~ 70
(1)
(2)

Other manuals for LG LFXS32726 Series

Related product manuals