EasyManua.ls Logo

LG LMXS28596S - Page 61

LG LMXS28596S
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-61-
Symptom Check Point
1. Over cooling in
Freezer compartment
1. Check the sensor resistance
2. Check the air flow
3. Check the air Temperature
4.Check the Fan motor sticky
5. Check the Fan motor voltage
8-17. Over cooling in Freezer compartment
Duct
Fan Motor
CON5 12
th
pin ~ 11
th
Pin Resistance [@
-22ºF / -30ºC 40k
-13ºF / -25ºC 30k
-4ºF / -20ºC 23k
-13ºF / -25ºC 17k
14ºF / -10ºC 13k
23ºF / -5ºC 10k
32ºF / 0ºC 8k
TEST MODE 1 Voltage [V]
jvuZG_

G¥G\

w
12V
jvu\G]

G¥G\

w
0V<Voltage<5V
jvu\G^

G¥G\

w
0V<Voltage<5V
Duct Status
Air Flow Windy
Air Temperature Cold
- 61 -
&RS\ULJKW   /* (OHFWURQLFV ,QF $OO ULJKWV
UHVHUYHG2QO\WUDLQLQJDQGVHUYLFHSXUSRVHV