What to do per LED Blinking and Trip protection Logic
4. Over Voltage Trip and LED Blinking 4 times (Over Voltage Trip)
Purpose : Protection the PCB by Over Voltage.
Cause : DC Link Over Voltage Input(over 450V
DC
)
Logic : After the Comp. Off every 90 seconds restart Comp.
LED 4 Blinks
Replace PCB
LED 4 Blinks
About 5min
Reset
Test Mode
1 Input
Blink Blink OFFBlink OFF Blink BlinkBlink BlinkBlink