What to do per LED Blinking and Trip protection Logic
7. IPM Fault Trip and LED Blinking 7 times (IPM Fault)
Purpose : Protection Over-Current by failure IPM(IPM short)
Cause : IPM Short and failure
Logic : After the Comp. Off every 20 seconds restart Comp.
Blink OFFBlink BlinkBlink BlinkBlinkBlink
LED
Blinking 7
times
Reset Replace PCB
LED
Blinking 7
times
- 89 -