3) Form the pipings
1. Wrap the connecting portion of indoor unit with
the Insulation material and secure it with two
Plastic Bands. (for the right pipings)
If you want to connect an additional drain hose,
the end of the drain-outlet should keep distance
from the ground. (Do not dip it into water, and fix it
on the wall to avoid swinging in the wind.)
2. Tape the pipings, drain hose and connecting
Cable from down to up.
3. Form the pipings gathered by taping along the
exterior wall and fix it onto the wall by saddle
or equivalent.
2. Tape the pipings and connecting cable from
down to up.
3. Form the pipings gathered by taping along the
exterior wall, make the Trap to be required to
prevent the room from entering the water.
4. Fix the pipings onto the wall by saddle or
equivalent.
In case of the outdoor unit to be installed below
position of the Indoor unit.
In case of the Outdoor unit to be installed upper
position of the Indoor unit.
Taping
Pipings
Connecting
cable
Drain
hose
Seal small openings around
pipings with a gum type sealer.
Trap is required to prevent water
from entering into electrical parts.