17) Poor Cooling in Freezer section
CHECKING FLOW RESULT & SERVICE ACTION
Check the conditions of gasket in freezer door
(gaps, damage, deformed).
1
2
NO.
Check the sensor resistance value in CON 6.
5
1) Open freezer door.
2) Press manually the freezer door S/W.
3) Check the air flow.
4
3
Result
Service Action
Go to Step 2
Ok
Abnormal
Fix up (if possible) or
change the Gasket
Reset product, then, enter to TEST MODE 1
(Press once).
Refer to temperature chart for Refrigerator Sensor.
Result
Service Action
Go to Step 3
Ok
Abnormal
Check section “3”
Abnormal Freezer
Sensor
Result
Service Action
Go to Step 4
Entered
Not entered
Execute DISPLAY
CHECK MODE, check
the result and match with
related error
ALL LED ON
Result
Service Action
Go to Step 5
Air flow
No Air flow
Go to Step 6
1) Enter to TEST MODE 2.
2) Open freezer door.
3) Press manually the freezer door S/W.
4) Check the air flow.
Result
Service Action
Go to Step 10
Air flow
No Air flow
Go to Step 6