EasyManua.ls Logo

LG LSC27914SB - Page 110

LG LSC27914SB
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17) Poor Cooling in Freezer section
CHECKING FLOW RESULT & SERVICE ACTION
1) Unplug Damper Motor
2) Check the Damper Motor impedance.
9
10
NO.
1) Reset product.
2) Enter to TEST MODE 1 (press once TEST S/W
on Main PCB).
1) Reset the refrigerator.
2) Enter to TEST MODE 1 (Press TEST S/W once).
3) Check Voltage in CON 1.
4) Enter to TEST MODE 2 (Press TEST S/W once
again).
5) Check Voltage in CON 1.
6) Proceed with the action.
4
5
6
1 2 3
Result
Service Action
~
Change PCB
369 ~ 451Ù
Other
Change Damper
~
Change PCB
369 ~ 451Ù
Other
Change Damper
1 6
2
5
~
3
4
129.6~158.4Ù
Change PCB
Change Damper
Other
Result
Service Action
Change Main PCB
Below 10 V
Other
Go to Step 11
Change Fan Motor
0V or 5V
Other
Go to Step 11
~
a
b
~
b
c
~
b
c
~
a
b
3) Check Voltage in CON 6 as shown in the pictures.
Result
Service Action
Change Main PCB
110~127Vac
Other
Bad compressor,
Refrigerant leakage, tube
obstruction, etc.
(Please refer to cycle
troubleshooting)
0~5 Vac
TEST
MODE 1
TEST
MODE 2
Other
Change Main PCB
Bad compressor,
Refrigerant leakage, tube
obstruction, etc.
(Please refer to cycle
troubleshooting)
11
- 109 -