CHECKING FLOW RESULT & SERVICE ACTION
Check the sensor resistance value in CON 7.
5
6
NO.
1) Remove Control Box in refrigerator sensor.
7
Result
Service Action
Go to Step 2
OK
Abnormal
Check Section 3 Abnormal
Refrigerator Sensor
Enter to TEST MODE 1 (Press once the TEST S/W
in Main PCB).
2) Check for any loose connection.
3) Turn On the refrigerator.
18) Over cooling in Refrigerator section
Refer to Temperature chart for Refrigerator Sensor.
Go to Step 3
1) Open Refrigerator door.
2) Press manually the refrigerator door S/W,
wait 10 seconds.
3) Check the air flow.
Result
Service Action
Go to Step 4
Air flow
No Air flow
Go to Step 6
Enter to TEST MODE 2 (Press once the TEST S/W
in Main PCB).
Go to Step 5
1) Open Refrigerator door.
2) Press manually the refrigerator door S/W.
3) Check the air flow.
Result
Service Action
Go to Step 6
Air flow
No Air flow
Go to Step 10
Turn Off the refrigerator. Go to Step 7
Connectors must be firmly connected, and wires don’t be
have any damage.
Next action: Go to Step 8.