6) Abnormal Ice maker Temperature Sensor Error
Check for a loose connection in CON8
on Main PCB.
In Freezer compartment remove Tray ice, remove
screw of Ice maker unit, quit Ice maker from holders
and check for any loose connection.
Result
Service Action
Firmly plugged
Loose
Go to Step 2
Result
Service Action
Firmly plugged
Loose
Go to Step 3
In the Main PCB, unplug CON8 and check between
Gray to Gray as is shown in the picture.
Result
Service Action
0 Ù
OFF
Plug CON 8, then, go to
Step 4
Other
Short
Open
Normal
Replace Main PCB
Unplug Ice maker unit and check value between
White to White.
1
2
NO.
CHECKING FLOW RESULT & SERVICE ACTION
3
4
Result
Service Action
0 Ù
OFF
Replace Ice Maker unit
Other
Short
Open
Normal
Replace product
- 85 -