18
7. Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as
following.
For Heating Model
8. Hot-Start Control
The indoor fan stops until the evaporator piping temperature will be reached to 28.
During heating operation, if piping temperatures falls below 26°C fan stops.
The operation diagram is as following.
PIPING
TEMPERATURE
1min
COMPRESSOR
INDOOR FAN
ON
26°C
: Selected Fan : Low Fan : Fan Stop
28°C

Other manuals for LG LV-B2461CL