5-16
Output i
s full power
when you set lower
pow
er level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective PCB
assembly.
Replace PCB
assembly.
NOTE : Make sure the wire leads correct position.
When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
CONDITION CHECK RESULT CAUSE REMEDY