Standard Repair Process Detail Technical Manual
Remote control operation checking method
D. Function error
A13
Established
date
Revised
date
Error
symptom
Content
A13
Checking order to check remote control
P4000
1 GND
2 +3.3V_NORMAL
3 +3.3V_NORMAL
4 +3.5V_ST
5 EYE_SDA_WALLMOUNT
6 OLED_ACCEL
7 EYE_SCL_WALLMOUNT
8 GND
9 EYE_SDA_STAND
10 GND
11 EYE_SCL_STAND
12 KEY1
13 GND
14 KEY2
15 IR
16 +3.5V_ST
17 LIGHT_WAFER
18 GND
①
②
③
Checking order
1, 2. Check IR cable condition between IR & Main board.
3. Check the st-by 3.5V on the terminal 4
Copyright © 2017 LG Electronics Inc. All rights reserved.
Only for training and service purposes.