5. DOWNLOAD AND CALIBRATION
- 106 -
1. Connect as Fig 6-2(RS232 serial cable is connected between COM port of PC and MON port of
TEST JIG, in general)
2. Set the Power Supply 4.0V
3. Set the 3
rd
, 4
th
of DIP SW ON state always
4. Press the Phone power key, if the Remote ON is used, 1
st
ON state
D. Procedure
1. Connect as Fig 6-2(RS232 serial cable is connected between COM port of PC and MON port of
TEST JIG, in general)
2. Power ON PC then enter into Windows 98(Remark : Windows 2000 system could be feasible)
3. Run AUTOCAL.exe, the AUTOCAL application window will be appeared.
LED Number Name Description
LED 1 Power Power is provided for Test Jig
LED 2 TA Indicate charging state of the phone battery
LED 3 UART Indicate data transfer state through the UART port
LED 4 MON Indicate data transfer state through the MON port
Table 5-4 LED Description