EasyManua.ls Logo

LG R410A - Page 134

LG R410A
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting Guide
134 Indoor Unit
Indoor unit
related error
Error
Code
Error Contents Meaning Main Causes
Error display
position
10
Failure of the fan motor
operation
Concerned
Remote controller
Panel Display
Disconnecting the fan motor connec-
tor / failure
Burn out of PCB within the motor etc.
The fan is locked by an interference
with another object.
Failure capacitor part (TD chassis)
➃➄➅➆
3) Disconnected or crushed wired
2) Remove housing terminal
1) Remove motor connector
PCB indoor unit
Unlock by reassembling etc.
Turn the fan with hand and check
whether it is locked
1) Check with naked eye
2) Check with naked eye
3) Check with naked eye
Repair or exchange motor
Exchange motor
Check the resistance value of
each terminal with the tester
Check the resistance of both
ends of the capacitor (Normal : )
Exchange capacitor
Exchange capacitor
Checking method
Measures
∞°
Cause of problem Checking method Measures
Normal resistance (±10% )
+-
TH chassis TD chassis
Tester
∞∞
102k 5M ~ 30M
235k
251k

Table of Contents