30
10
COMPONENT TESTING INFORMATION
ComponentTest ProcedureCheck result
3. Outlet Thermostat
( Thermal cut off)
Check Top Marking:
C8-7
NT101
NT102
Measure resistance of terminal
Measure resistance of terminal
to terminal
Open at 230
(110
Open at 110
(110
Close at -31
(-351
Resistance value
Resistance value 5
Blow housing -
Safety
5. Idler switch Measure resistance of the
See Page 31
following terminal:
COM - NC
1. lever open
Resistance value 1
2. Lever push (close)
Resistance value
4. Door switch
following terminal
1) Door switch knob: open
Terminal: COM - NC (1-3)
Terminal: COM - NO (1-2)
2) Door switch push: push
Terminal: COM - NC (1-3)
Terminal: COM - NO (1-2)
Resistance value 1
Resistance value
Resistance value
Resistance value 1
If the knob is
pressed, the
state is the
opposite of
what is on the
chart.
WARNING
ailure to follow these instructions can result in death or electric shock.
-4 221
.
7.
1.
2. Safely limits thermostat
(Manual reset)
(-20  105 )